Taxanaha R3 Pre roverter waxaa si gaar ah loogu talagalay mashruucyo ganacsi oo saddex waji leh iyo degaan. Iyada oo nashqaddeeda is haysta, rogaha taxanaha R3 Pre ayaa 40% ka fudud jiilkii hore. Waxtarka beddelka ugu badan wuxuu gaari karaa 98.5%. Wax gelinta ugu badan ee xadhkaha kastaa waxa ay gaartaa 20A, kaas oo si fiican ula qabsan kara moduleka awooda sare si loo kordhiyo korontada.
Max. PV
hadda gelin
AFCI ikhtiyaari ah
shaqada ilaalinta
150% PV
galinta xad dhaafka ah
Kala duwanaanshaha korantada MPPT ballaaran (180 ~ 1000V)
| Qaabka | R3-15K | R3-20K | R3-25K |
| Max. Voltage PV Input[V] | 1100 | ||
| Max. Soo gelinta PV Hadda [A] | 40/40 | ||
| No.of MPPT Trackers/No.of Input Strings per Tracker | 2/2 | ||
| Max. Awoodda Muuqata ee AC [VA] | 16500 | 22000 | 27500 |
| Ugu badnaan.Waxqabad | 98.6% | ||
Taxanaha R3 Pre roverter waxaa si gaar ah loogu talagalay mashruucyo ganacsi oo saddex waji leh iyo degaan. Iyada oo nashqaddeeda is haysta, rogaha taxanaha R3 Pre ayaa 40% ka fudud jiilkii hore. Waxtarka beddelka ugu badan wuxuu gaari karaa 98.5%. Wax gelinta ugu badan ee xadhkaha kastaa waxa ay gaartaa 20A, kaas oo si fiican ula qabsan kara moduleka awooda sare si loo kordhiyo korontada.
Soo deji wax badan (1) Kahor intaanad adeegin, marka hore ka saar xidhiidhka korantada ee udhaxeeya inverter iyo grid, ka dibna ka saar korantada dhinaca DC (isku xirka. Waa lagama maarmaan in la sugo ugu yaraan 5 daqiiqo ama ka badan si loogu oggolaado inverter's capacitors awoodda sare ee gudaha iyo qaybaha kale in si buuxda loo saaro ka hor inta aan la fulin shaqada dayactirka.
(2) Inta lagu jiro hawlgalka dayactirka, marka hore, si muuqaal ah u hubi qalabka marka hore waxyeello ama xaalado kale oo khatar ah, oo fiiro gaar ah u leh anti-static inta lagu jiro hawlgalka gaarka ah, waxa ugu wanaagsan in la xidho giraanta gacanta ee anti-static. Si aad u fiirsato calaamadda digniinta ee qalabka, fiiro gaar ah u yeelo dusha rogayaasha ee la qaboojiyey. Isla mar ahaantaana si looga fogaado xidhiidhka aan loo baahnayn ee u dhexeeya jidhka iyo guddiga wareegga.
(3) Ka dib dayactirka la dhammeeyo, hubi in wixii khalad ah ee saameeya waxqabadka bedqabka beddelka in la xalliyo ka hor inta aanad dib u shidin qalabka wax beddelaya.
Sababta dhacdada:
(1) Korontada wax soo saarka ee moduleka ama xadhiggu waa ka hooseeyaa tamarta shaqada ee ugu yar ee rogaha.
(2) Polarity-ga gelinta ee xadhiggu waa la rogay. Dareemaha gelinta DC ma xidhna.
(3) Dareemaha gelinta DC ma xidhna.
(4) Mid ka mid ah xirayaasha xarigga si sax ah uguma xirna.
(5) Qayb waa wareeg gaaban, taasoo keenaysa in xargaha kale ay ku fashilmaan inay si sax ah u shaqeeyaan.
Xalka:
Ku cabbir danab gelinta DC ee beddelkaha oo leh danabka DC ee multimeterka, marka danabku caadi yahay, wadarta danabku waa wadarta korantada qayb kasta oo xadhig ah. Haddii aysan jirin wax danab ah, tijaabi in kala-duwayaasha DC-ga, xannibaadda terminalka, xiriiriyaha fiilada, sanduuqa isku xirka, iwm. Haddii ay jiraan xadhko badan, kala saar iyaga si gooni ah baaritaanka gelitaanka shakhsi ahaaneed. Haddii aysan jirin wax cillad ah oo ku yimaada qaybaha dibadda ama khadadka, waxay ka dhigan tahay in wareegga qalabka gudaha ee beddelka uu khaldan yahay, waxaadna la xiriiri kartaa Renac si aad u dayactirto.
Sababta dhacdada:
(1) Wax-soo-saarka inverter-ka AC ma xidhna.
(2) Xargaha wax-soo-saarka inverter-ka AC si sax ah uguma xirna.
(3) Marka fiilooyinka, safka sare ee terminalka wax soo saarka inverter waa dabacsan.
Xalka:
Cabbir danabka wax soo saarka AC ee rookaha leh qalab koronto AC multimeter ah, xaaladaha caadiga ah, terminals wax soo saarka waa in ay leeyihiin AC 220V ama AC 380V danab; haddaysan ahayn, markeeda, tijaabi xargaha xargaha si aad u aragto inay dabacsan yihiin iyo in kale, haddii furaha wareegga AC uu xiran yahay, furaha ilaalinta qulqulka ayaa go'an iwm.