Isishwankathelo
Khuphela & Inkxaso

High Voltage Hybrid lnverter

N3 Plus

15kW / 20kW / 25kW / 30kW | Isigaba esiThathu, iiMPPT ezi-3

Uluhlu lwe-N3 Plus lwe-inverters yokugcina amandla ombane aphezulu amanqanaba amathathu axhasa uxhulumaniso oluhambelanayo, okwenza lufaneleke kungekuphela nje kumakhaya okuhlala kodwa nakwizicelo ze-C&I. Ngokusebenzisa i-peak shaving kunye nokuzaliswa kwentlambo yamandla ombane, kunokunciphisa iindleko zombane kunye nokuphumeza ulawulo lwamandla oluzimeleyo. Igalelo lePV eliguquguqukayo kunye neeMPPT ezintathu, kwaye ixesha lokutshintsha lingaphantsi kwe-10 milliseconds. Ixhasa ukhuseleko lwe-AFCI kunye nomgangatho wokhuseleko lwe-TypeⅡ DC/AC surge, ukuqinisekisa ukusetyenziswa kombane okukhuselekileyo.

  • 18A

    Max. PV

    igalelo langoku

  • <10ms

    Ixesha lokutshintshela

  • 100%
    Imithwalo engalungelelananga
Iimpawu zeMveliso
  • 图标_IP66 uyilo lwangaphandle
    IP66 uyilo lwangaphandle
  • 图标_Generator-iyahambelana ukwandisa ugcino

    Ijenereyitha-iyahambelana ukwandisa ugcino

  • Inkxaso 100 off igridi imithwalo engalinganiyo transformerless

    I-110% yokulayishwa kwe-AC

  • Usetyenziso olungakumbi lwe-AC

    Inkxaso AC retrofit isicelo

Uluhlu lweParameter
Umzekelo N3-15K N3-20K N3-25K N3-30K
Max. Igalelo lePV langoku [A] 36/36/36
Max. I-AC Output Apparent Power [VA] 16500 22000 27500 33000
Uluhlu lweBattery Voltage [V] 180 ~ 800
Max. Ukutshaja / Ukukhupha okwangoku [A] 50/50
NONE 15000 20000 25000 30000
Ugcino lweNcopho olubonakalayo lwaMandla,
Ubude bexesha [VA, s]
22500, 10 30000, 10 37500, 10 45000, 10

High Voltage Hybrid lnverter

15kW / 20kW / 25kW / 30kW | Isigaba esiThathu, iiMPPT ezi-3

Uluhlu lwe-N3 Plus lwe-inverters yokugcina amandla ombane aphezulu amanqanaba amathathu axhasa uxhulumaniso oluhambelanayo, okwenza lufaneleke kungekuphela nje kumakhaya okuhlala kodwa nakwizicelo ze-C&I. Ngokusebenzisa i-peak shaving kunye nokuzaliswa kwentlambo yamandla ombane, kunokunciphisa iindleko zombane kunye nokuphumeza ulawulo lwamandla oluzimeleyo. Igalelo lePV eliguquguqukayo kunye neeMPPT ezintathu, kwaye ixesha lokutshintsha lingaphantsi kwe-10 milliseconds. Ixhasa ukhuseleko lwe-AFCI kunye nomgangatho wokhuseleko lwe-TypeⅡ DC/AC surge, ukuqinisekisa ukusetyenziswa kombane okukhuselekileyo.

KhuphelaKhuphela Okunye

Ividiyo yeMveliso

Intshayelelo yemveliso
Ukufakwa kwemveliso

FAQs ezinxulumeneyo

  • 1.Yintoni ekufuneka uyijonge xa ​​usebenzisa i-inverter?

    (1) Ngaphambi kokuba usebenze, okokuqala unqande uxhulumaniso lombane phakathi kwe-inverter kunye negridi, kwaye emva koko unqande umbane wecala le-DC (uqhagamshelo. Kuyimfuneko ukulinda ubuncinane imizuzu emi-5 okanye ngaphezulu ukuvumela i-capacitors yangaphakathi ye-inverter ephezulu kunye nezinye izinto ukuba zikhutshwe ngokupheleleyo ngaphambi kokwenza umsebenzi wokulondoloza.

     

    (2) Ngexesha lomsebenzi wokulondoloza, okokuqala, jonga ngokubonakalayo izixhobo ekuqaleni umonakalo okanye ezinye iimeko ezinobungozi, kwaye ubeke ingqalelo kwi-anti-static ngexesha lomsebenzi othile, kungcono ukunxiba i-anti-static hand ring. Ukunyamekela kwileyibhile yesilumkiso kwisixhobo, nikela ingqalelo kwi-inverter surface epholile phantsi. Ngexesha elifanayo ukuphepha uqhagamshelwano olungeyomfuneko phakathi komzimba kunye nebhodi yesekethe.

     

    (3) Emva kokuba ukulungiswa kugqityiwe, qiniseka ukuba naziphi na iimpazamo ezichaphazela ukusebenza kokhuseleko lwe-inverter zixazululwe ngaphambi kokuguqula i-inverter kwakhona.

  • 2.Siyintoni isizathu sokuba isikrini sokuguqula isikrini singabonisi? Indlela yokusombulula ngayo?

    Unobangela wokwenzeka:

    (1) I-voltage ephumayo yemodyuli okanye intambo iphantsi kunombane omncinci wokusebenza we-inverter.

    (2) I-polarity yegalelo lomtya ibuyiselwe umva. Ukutshintsha igalelo leDC alivalwanga.

    (3) I-DC input switch ayivalwanga.

    (4) Esinye seziqhagamshelo kumtya asidityaniswanga kakuhle.

    (5) Icandelo lifutshane, libangela ukuba ezinye iintambo zingasebenzi kakuhle.

     

    Isisombululo:

    Ukulinganisa i-voltage yegalelo le-DC ye-inverter kunye ne-DC yombane we-multimeter, xa i-voltage iqhelekile, i-voltage iyonke sisimbuku sombane wecandelo kumtya ngamnye. Ukuba akukho mbane, vavanya ukuba ngaba i-DC circuit breaker, i-terminal block, i-cable connector, ibhokisi ye-junction yecandelo, njl. njl. Ukuba kukho iintambo ezininzi, zikhuphe ngokwahlukeneyo kuvavanyo lofikelelo lomntu ngamnye. Ukuba akukho ukungaphumeleli kwamacandelo angaphandle okanye imigca, kuthetha ukuba isiphaluka se-hardware yangaphakathi ye-inverter iphosakele, kwaye unokuqhagamshelana ne-Renac yokugcinwa.

  • 3.I-inverter ibonisa impazamo yegridi kwaye ibonise umyalezo wempazamo njengempazamo yamandla ombane "iGrid Volt Fault" okanye impazamo yamatyeli "Grid Freq Fault" "Grid Fault"?

    Unobangela wesehlo: 

    Umbane kunye nokuphindaphinda kwegridi yamandla e-AC angaphandle koluhlu oluqhelekileyo.

     

    Isisombululo:

    Ukulinganisa i-voltage kunye nokuphindaphinda kwegridi yamandla e-AC kunye nesixhobo esifanelekileyo se-multimeter, ukuba ayiqhelekanga ngokwenene, linda ukuba igridi yamandla ibuyele kwisiqhelo. Ukuba i-voltage yegridi kunye ne-frequency iyinto eqhelekileyo, oko kuthetha ukuba i-circuit ye-inverter yokufumanisa iphosakele. Xa ujonga, qala uqhawule igalelo le-DC kunye nemveliso ye-AC ye-inverter, kwaye uvumele i-inverter ibe namandla ngaphezu kwe-30min ukuze ubone ukuba isekethe inokubuyisela ngokwayo, ukuba inokubuyisela ngokwayo, ungaqhubeka ukuyisebenzisa, ukuba ayikwazi ukufunyanwa, ungaqhagamshelana.Renacukutshintshwa okanye ukutshintshwa. Ezinye iisekethe ze-inverter, ezifana ne-inverter main board circuit, isekethe yokufumanisa, isekethe yonxibelelwano, i-inverter circuit, kunye nezinye iimpazamo ezithambileyo, zingasetyenziselwa ukuzama le ndlela ingasentla ukubona ukuba ziyakwazi ukuzibuyisela ngokwazo, kwaye emva koko zigqithise okanye zitshintshe ukuba azikwazi ukubuyisela ngokwabo.