I-PV inverter i-R3 Max series, i-inverter yesigaba esithathu ehambelana nomthamo omkhulu we-PV panels, isetyenziswa ngokubanzi kwiinkqubo ze-PV ezisasazwayo kunye nezityalo zamandla ze-PV ezinkulu. ixhotyiswe ngokhuseleko lwe-IP66 kunye nolawulo lwamandla olusebenzayo. Ixhasa ukusebenza kakuhle okuphezulu, ukuthembeka okuphezulu, kunye nofakelo olulula.
Max. PV
igalelo langoku
Ukhetho lwe-AFCI & Smart
Umsebenzi wokubuyisela i-PID
Uyilo lwangaphandle
I-150% yePV igalelo eligqithisiweyo kunye ne-110% yokulayishwa kwe-AC
Ukujongwa komtya kunye nexesha elifutshane le-O&M
| Umzekelo | I-R3-100K | I-R3-110K | I-R3-125K |
| Max. I-PV Input Voltage[V] | 1100 | ||
| Max. Igalelo lePV langoku ngeMPPT [A] | 32 | ||
| Inombolo yeMPPT Trackers/No.of Input strings per Tracker | 9/2 | ||
| Max. I-AC Output Apparent Power [VA] | 11000 | 121000 | 125000 |
| Max.Ubuchule | 98.7% | ||
I-PV inverter i-R3 Max series, i-inverter yesigaba esithathu ehambelana nomthamo omkhulu we-PV panels, isetyenziswa ngokubanzi kwiinkqubo ze-PV ezisasazwayo kunye nezityalo zamandla ze-PV ezinkulu. ixhotyiswe ngokhuseleko lwe-IP66 kunye nolawulo lwamandla olusebenzayo. Ixhasa ukusebenza kakuhle okuphezulu, ukuthembeka okuphezulu, kunye nofakelo olulula.
Khuphela Okunye Unobangela wesehlo:
Isizathu salo siphoso yingxaki yonxibelelwano phakathi kwee-CPU eziphambili kunye neesekondari zebhodi yokulawula inverter.
Isisombululo:
(1)Rqalisa i-inverter (kufuneka ukhuphe i-PV, igridi ye-AC, kunye neebhetri kwaye emva koko uyivule kwakhona).
(2) Ukuba ingxaki iyaqhubeka emva kokuqalisa kwakhona i-inverter, khangela ukuba i-software version yebhodi yokulawula inverter ichanekile. Ukuba akunjalo, zama ukutshisa kwisoftware kwakhona.
(3) Ukuba ingxaki iyaqhubeka emva kokutshisa isofthiwe, buyisela ibhodi yokulawula.
Unobangela wesehlo:
Umbane kunye nokuphindaphinda kwegridi yamandla e-AC angaphandle koluhlu oluqhelekileyo.
Isisombululo:
Ukulinganisa i-voltage kunye nokuphindaphinda kwegridi yamandla e-AC kunye nesixhobo esifanelekileyo se-multimeter, ukuba ayiqhelekanga ngokwenene, linda ukuba igridi yamandla ibuyele kwisiqhelo. Ukuba i-voltage yegridi kunye ne-frequency iyinto eqhelekileyo, oko kuthetha ukuba i-circuit ye-inverter yokufumanisa iphosakele. Xa ujonga, qala uqhawule igalelo le-DC kunye nemveliso ye-AC ye-inverter, kwaye uvumele i-inverter ibe namandla ngaphezu kwe-30min ukuze ubone ukuba isekethe inokubuyisela ngokwayo, ukuba inokubuyisela ngokwayo, ungaqhubeka ukuyisebenzisa, ukuba ayikwazi ukufunyanwa, ungaqhagamshelana.Renacukutshintshwa okanye ukutshintshwa. Ezinye iisekethe ze-inverter, ezifana ne-inverter main board circuit, isekethe yokufumanisa, isekethe yonxibelelwano, i-inverter circuit, kunye nezinye iimpazamo ezithambileyo, zingasetyenziselwa ukuzama le ndlela ingasentla ukubona ukuba ziyakwazi ukuzibuyisela ngokwazo, kwaye emva koko zigqithise okanye zitshintshe ukuba azikwazi ukubuyisela ngokwabo.
Unobangela wesehlo:
Ngokukodwa ngenxa yokuba i-impedance yegridi inkulu kakhulu, xa icala lomsebenzisi we-PV lokusetyenziswa kwamandla lincinci kakhulu, ukuhanjiswa kwe-impedance kuphezulu kakhulu, okukhokelela ekubeni icala le-AC inverter ye-voltage ephumayo iphezulu kakhulu!
Isisombululo:
1 Okukhona ikhebula lijiyile, kokukhona i-impedance isezantsi.
(2) I-inverter isondele ngokusemandleni kwindawo edibeneyo yegridi, imfutshane ikhebula, i-impedance ephantsi. Ngokomzekelo, thatha i-inverter ye-5kw edibeneyo yegridi njengomzekelo, ubude bekhebula lokuphuma kwe-AC ngaphakathi kwe-50m, ungakhetha indawo ye-cross-sectional ye-2.5mm2 intambo: ubude be-50 - 100m, kufuneka ukhethe indawo ye-cross-sectional ye-4mm2 cable: ubude obukhulu kune-100m, kufuneka ukhethe indawo ye-cross-section2.