Uhlolojikelele
Landa & Ukusekela

High Voltage Ibhethri

I-Turbo H1

3.74kWh / 7.48kWh / 11.23kWh / 14.97kWh / 18.7kWh

I-RENAC Turbo H1 iyi-voltage ephezulu, imojula yokugcina ibhethri esheshayo. Inikeza imodeli engu-3.74 kWh engakwazi ukunwetshwa ochungechungeni ngamabhethri afika kwangu-5 namandla angu-18.7kWh. Ukufakwa kalula ngepulaki nokudlala.

  • > 6000

    Izikhathi zokuphila komjikelezo

  • 5amayunithi

    Sekela amaqoqo angafika kwangu-5

    uxhumano parallel

  • IP65
    IP65 idizayini yangaphandle
Izici Zomkhiqizo
  • 图标_Amamojula aqinile, ipulaki nedizayini yokudlala
    amamojula stackable,
    ipulaki & nomklamo wokudlala
  • 图标_Max. ukushaja - ukushajwa kwamanje kwe-100 - 135A

    Izinga lokushaja eliphezulu / lokukhulula

  • 图标_Flexible umthamo-izinketho

    Izinketho zamandla aguquguqukayo

  • Ukuthuthukiswa nokulungiselelwa kwe-firmware yesilawuli kude

    Ukuthuthukiswa kwe-firmware ekude kanye

    ukuxilongwa nge-inverter

Uhlu Lwepharamitha
Imodi I-TB-H1-3.74 I-TB-H1-7.48 I-TB-H1-11.23 I-TB-H1-14.97 I-TB-H1-18.7
Inombolo yamamojula 1 2 3 4 5
Amandla Okuzisholo[kWh] 3.74 7.48 11.23 14.97 18.7
I-Nominal Voltage[V] 96 192 288 384 480
Ubukhulu.Ukushaja Okuqhubekayo/
Ikhipha Yamanje[A]
30/30
I-Ingress Protection IP65

High Voltage Ibhethri

3.74kWh / 7.48kWh / 11.23kWh / 14.97kWh / 18.7kWh

I-RENAC Turbo H1 iyi-voltage ephezulu, imojula yokugcina ibhethri esheshayo. Inikeza imodeli engu-3.74 kWh engakwazi ukunwetshwa ochungechungeni ngamabhethri afika kwangu-5 namandla angu-18.7kWh. Ukufakwa kalula ngepulaki nokudlala.

downloadKhipha ku-internet Okuningi

Ividiyo Yomkhiqizo

Isingeniso somkhiqizo
Ukufakwa komkhiqizo

Imibuzo Evame Ukubuzwa Ehlobene

  • 1.Yini iphutha elithi “BMS AD_AFE Fault” lebhethri le-Turbo H1?

    Inkinga ibangelwa umehluko omkhulu phakathi kwe-“Total Cell voltage” kanye “ne-voltage ye-AD System” yebhethri, umehluko udlula u-15%, yenza ukulinganisa kwe-BMC noma uthuthukise i-BMC ibe inguqulo yakamuva ye-firmware, udaba lungaxazululeka. Uma inkinga isaqhubeka, sicela ushintshe i-BMC.

  • 2.Yini iphutha elithi “Battery Volt Fault” lebhethri le-Turbo H1?

    Inkinga ibangelwa ugesi ongavamile webhethri. Sicela uhlole ukuthi i-voltage yebhethri ijwayelekile yini. Uma i-voltage yebhethri iyinkinga, hlola ibhethri noma uxhumano lwebhethris. Uma i-voltage yebhethri ijwayelekile,kodwa udaba lusekhona, ngiyacelahlola ukuthi i-inverter iyakwazi ukubona i-voltage yebhethri. Uma i-voltage yebhethri ingabonakalinge-inverter, sicela uhlole ukuthi amandlaikhebula phakathi kwe-inverter nebhethri bheka ukuthi likhona yini's isesimweni esihle(ngezinye izikhathi ngenxa yokuthi amatheminali ebhethri awacishwangangokuqinile). Uma ukuxazulula inkinga okungenhlakwenziwekodwa inkinga iphikelela, buyiselazama ukufaka esikhundlenii-BMC.

  • 3.Kungani ibhethri ye-Turbo H1 ihlezi igxuma i-SOC noma ingashajwa kuphela ku-SOC ethile futhi ayikwazi ukushajwa ku-100%?

    Isizathu esiyinhloko ukuthi uma umsebenzisi enqwabelanisa amabhethri, i-SOC yebhethri ngalinye ayifani, okubangela ukuthi isistimu ingene esimweni esinokulinganisela.

    Isixazululo:

    Xhuma ibhethri ngalinye ngokuhlukile ku-inverter, uyishaje ku-20% noma u-30%, bese uyikhipha ku-10%, bese ukala i-voltage yebhethri, ngokuvamile engu-97V, qinisekisa ukuthi wonke amandla ebhethri angu-97V, xhuma amabhethri ndawonye, ​​uwashaje ku-20% noma 30% ngesiguquli, bese usetha i-inverter ngokuthi "self-user mode".

  • 4.Iwarehouse iwaphatha kanjani lawa mabhethri e-Turbo H1?

    Imojula yebhethri kufanele igcinwe ihlanzekile, yomile, futhi ingenisa umoya endlini ngebanga lokushisa eliphakathi kuka -10℃~+35℃, igweme ukuthintana nezinto ezonakalisayo, kude nemithombo yomlilo neyokushisa, futhi ishajwe njalo ngemva kwezinyanga eziyisithupha ngokungekho ngaphezu kuka-0.5C(C-rate isilinganiso sezinga lapho ibhethri liphuma khona ngokuhlobene nomthamo walo omkhulu wesikhathi eside esingu-40% we-SOC.)

  • 5.Ingabe ngidinga ukufaka iswishi ye-DC yangaphandle phakathi kwe-Turbo H1 BMC ne-inverter?

    Cha, sesivele sineswishi ye-DC ku-BMC futhi asikuphakamisi ukuthi wengeze iswishi ye-DC yangaphandle phakathi kwebhethri ne-inverter. Ngoba kungase kube nomthelela ekusebenzeni kokushajwa kwangaphambili kwebhethri futhi kubangele ukulimala kwehadiwe kukho kokubili ibhethri ne-inverter uma uvula iswishi ye-DC yangaphandle ngemva kwesikhathi kunebhethri nesiguquli. Uma usuvele uyifakile sicela uqiniseke ukuthi isinyathelo sokuqala sivula iswishi ye-DC yangaphandle, bese uvula ibhethri ne-inverter.