Uhlolojikelele
Landa & Ukusekela

I-Inverter ye-On-Grid

R1 Macro

3.68kW / 5kW / 6kW | Isigaba Esisodwa, 2 MPPTs

I-RENAC R1 Macro Series iyisiguquli sesigaba esisodwa segridi enosayizi ohlangene oncomekayo, isoftware ephelele kanye nobuchwepheshe behadiwe. Uchungechunge lwe-R1 Macro lunikeza ukusebenza kahle okuphezulu kanye nedizayini ehamba phambili esebenza ngaphandle kwabalandeli, enomsindo ophansi.

  • 16A

    Ubukhulu. I-PV

    okokufaka kwamanje

  • I-AFCI

    I-AFCI yokuzithandela

    umsebenzi wokuvikela

  • 150%

    I-PV engu-150%.

    ukufaka usayizi oweqile

Izici Zomkhiqizo
  • Thekelisa
    Umsebenzi wokulawula ukuthekelisa uhlanganisiwe
  • 2
    Ukuvikelwa kwezinga lokushisa elingaphezulu
  • 特征图标-2
    Thayipha II SPD kukho kokubili i-DC ne-AC
  • 特征图标-3
    Ukuthuthukiswa nokulungiselelwa kwe-firmware yesilawuli kude
Uhlu Lwepharamitha
Imodeli R1-3.68K R1-5K R1-6K
Ubukhulu. I-PV Input Voltage[V] 600
Ubukhulu. Okokufaka kwe-PV Yamanje [A] 16/16
Inombolo Yama-MPPT Trackers/No.of Input Strings nge-Tracker ngayinye 2/1
Ubukhulu. Amandla abonakalayo okukhipha i-AC [VA] 3680 5500 6000
Ukusebenza kahle okuphezulu 97.9%

I-Inverter ye-On-Grid

3.68kW / 5kW / 6kW | Isigaba Esisodwa, 2 MPPTs

I-RENAC R1 Macro Series iyisiguquli sesigaba esisodwa segridi enosayizi ohlangene oncomekayo, isoftware ephelele kanye nobuchwepheshe behadiwe. Uchungechunge lwe-R1 Macro lunikeza ukusebenza kahle okuphezulu kanye nedizayini ehamba phambili esebenza ngaphandle kwabalandeli, enomsindo ophansi.

downloadKhipha ku-internet Okuningi

Ividiyo Yomkhiqizo

Isingeniso somkhiqizo
Ukufakwa komkhiqizo

Imibuzo Evame Ukubuzwa Ehlobene

  • 1.Kungani i-"Vgrid 10M Fault" iboniswa esikrinini se-inverter?

    Imbangela yesigameko:

    I-voltage yegridi ingaphandle kwebanga elijwayelekile lokuphepha.

    (1) Amakhebuli abasebenzisi ayaguga noma agcwele ngokweqile, okubangela ukuntengantenga kwamandla kagesi kanye nokuguquguquka.

    (2) Ukungaqini kwegridi yendawo ngesikhathi sokusetshenziswa kukagesi okuphezulu.

     

    Isixazululo:

    (1) Shintshanisa izintambo zokubopha noma unciphise ukufinyelela komthwalo ukuze kuthuthukiswe ukuzinza kwamandla kagesi okufinyelela komsebenzisi.

    (2) Qinisekisa ukusebenza okuvamile kwe-inverter ngokulungisa ububanzi be-voltage ephumayo.

  • 2."Iphutha le-voltage yebhasi" esikrinini se-inverter.

    Imbangela yesigameko:

    I-voltage yebhasi ingaphezu kwezinga elibekwe isofthiwe. 

    Isixazululo:

    (1) Ukuze uvale i-inverter, kufanele uqale ucime imithombo yamandla ye-DC ne-AC, ulinde imizuzu engu-5, bese uyixhuma futhi bese uqala kabusha i-inverter.

    (2) Umausenayoiphuthaumyalezo, hlola ukuthi amandla kagesi e-DC/AC ayadlula yini izimfuneko zokucaciswa kwepharamitha. Uma kwenzeka,ngconongokushesha.

    (3) Uma iphutha liqhubeka, i-hardware ingase yonakaliswe. Sicela uxhumane nesifaki sakho noma umhlinzeki wesevisi.