Dubawa
Zazzagewa & Tallafi

On-Grid Inverter

R1 macro

3.68kW / 5kW / 6kW | Mataki Daya, 2 MPPTs

RENAC R1 Macro Series shine mai jujjuyawar kan-grid mataki-daya tare da ingantacciyar girman girman, cikakkiyar software da fasahar kayan masarufi. Jerin R1 Macro yana ba da ingantaccen inganci da aikin ja-gorancin aji, ƙira mara ƙarancin hayaniya.

  • 16A

    Max. PV

    shigar da halin yanzu

  • AFCI

    AFCI na zaɓi

    aikin kariya

  • 150%

    150% PV

    shigarwar oversizing

Siffofin Samfur
  • fitarwa
    Haɗaɗɗen aikin sarrafa fitarwa
  • 2
    Kariyar yawan zafin jiki
  • 特征图标-2
    Nau'in II SPD don duka DC da AC
  • 特征图标-3
    Haɓaka firmware mai nisa & saiti
Jerin Ma'auni
Samfura R1-3.68K R1-5K R1-6K
Max. PV Input Voltage[V] 600
Max. Shigar da PV na Yanzu [A] 16/16
No.na MPPT Trackers/No.of Input Strings per Tracker 2/1
Max. Ƙarfin Fitar da AC [VA] 3680 5500 6000
Matsakaicin inganci 97.9%

On-Grid Inverter

3.68kW / 5kW / 6kW | Mataki Daya, 2 MPPTs

RENAC R1 Macro Series shine mai jujjuyawar kan-grid mataki-daya tare da ingantacciyar girman girman, cikakkiyar software da fasahar kayan masarufi. Jerin R1 Macro yana ba da ingantaccen inganci da aikin ja-gorancin aji, ƙira mara ƙarancin hayaniya.

zazzagewaSauke Ƙari

Bidiyon Samfura

Gabatarwar samfur
Shigar da samfur

FAQs masu alaƙa

  • 1.Me yasa "Vgrid 10M Fault" ke nunawa akan allon inverter?

    Dalilin faruwar hakan:

    Wutar lantarki na grid yana waje da daidaitaccen kewayon aminci.

    (1) Kebul na mai amfani tsufa ko ɗora nauyi, yana haifar da rashin kwanciyar hankali da haɓaka.

    (2) Rashin kwanciyar hankali na gida yayin yawan amfani da wutar lantarki.

     

    Magani:

    (1) Sauya kayan aikin wayoyi ko rage damar lodi don inganta kwanciyar hankalin wutar lantarki mai amfani.

    (2) Tabbatar da aiki na yau da kullun na inverter ta hanyar daidaita iyakar ƙarfin fitarwa.

  • 2"Bus voltage Fault" akan allon inverter.

    Dalilin faruwar hakan:

    Wutar lantarkin motar bas yana sama da ma'aunin da software ta saita. 

    Magani:

    (1) Don kashe inverter, sai ka fara kashe wutar lantarki na DC da AC, jira na mintuna 5, sannan ka sake haɗa su sannan ka sake kunna inverter.

    (2) Idanhar yanzu suna dakuskuresako, duba idan wutar lantarki ta DC/AC ta zarce ƙayyadaddun buƙatun siga. Idan yayi,ingantashi da sauri.

    (3) Idan kuskuren ya ci gaba, kayan aikin na iya lalacewa. Da fatan za a tuntuɓi mai sakawa ko mai bada sabis.