Dulmar
Soo dejiso & Taageer

Inverter on-Grid

R3 Navo

30kW / 50kW | Saddex waji, 3/4 MPPT

RENAC R3 Navo Series inverter waxaa si gaar ah loogu talagalay mashaariicda warshadaha yar yar iyo kuwa ganacsiga. Naqshadaynta bilaashka ah ee fiyuuska ah, shaqada AFCI ee ikhtiyaarka ah iyo ilaalin kale oo badan, waxay xaqiijinaysaa heerka badbaadada sare ee hawlgalka. Iyadoo max. Hufnaanta 99%, ugu badnaan korantada gelinta DC ee 11ooV, baaxadda MPPT ballaaran iyo danab bilawga hoose ee 200V, waxay dammaanad qaadaysaa jiil hore oo awood ah iyo waqti dheer oo shaqo. Nidaamka hawo-qaadista ee horumarsan, rogaha ayaa si hufan u daadiya kulaylka.

  • 20A

    Max. PV

    hadda gelin

  • AFCI

    AFCI Ikhtiyaar ah & Smart

    Shaqada soo kabashada PID

  • 200v

    Bilow hoose

    danab ku saabsan 200V

Tilmaamaha Alaabta
  • Dhoofinta
    Hawsha xakamaynta dhoofinta oo isku dhafan
  • 图标-06

    150% gelinta PV xad dhaafka ah & 110% culeyska AC

  • 3
    Nooca II SPD ee DC iyo AC labadaba
  • 特征图标-3

    Kormeerka xadhigga iyo wakhtiga O&M oo gaaban

Liiska Parameter
Qaabka R3-30K R3-40K R3-50K
Max. Voltage PV Input[V] 1100
Max. Soo gelinta PV Hadda [A] 40/40/40 40/40/40/40 40/40/40/40
No.of MPPT Trackers/No.of Input Strings per Tracker 3/2 4/2
Max. Awoodda Muuqata ee AC [VA] 33000 44000 55000
Ugu badnaan.Waxqabad 98.6% 98.8%

Inverter on-Grid

30kW / 50kW | Saddex waji, 3/4 MPPT

RENAC R3 Navo Series inverter waxaa si gaar ah loogu talagalay mashaariicda warshadaha yar yar iyo kuwa ganacsiga. Naqshadaynta bilaashka ah ee fiyuuska ah, shaqada AFCI ee ikhtiyaarka ah iyo ilaalin kale oo badan, waxay xaqiijinaysaa heerka badbaadada sare ee hawlgalka. Iyadoo max. Hufnaanta 99%, ugu badnaan korantada gelinta DC ee 11ooV, baaxadda MPPT ballaaran iyo danab bilawga hoose ee 200V, waxay dammaanad qaadaysaa jiil hore oo awood ah iyo waqti dheer oo shaqo. Nidaamka hawo-qaadista ee horumarsan, rogaha ayaa si hufan u daadiya kulaylka.

soo dejisoSoo deji wax badan

Fiidiyowga Alaabta

hordhaca alaabta
Ku rakibida alaabta

Su'aalaha la xiriira

  • 1.DC dhinaca gelin danab alaarmiga overvoltage, fariinta qaladka "PV Overvoltage" bandhigay?

    Sababta dhacdada:

    Qaybo aad u badan ayaa si isdaba joog ah ugu xidhan, taas oo keenaysa in danabka wax gelinta ee dhinaca DC uu dhaafo ugu badnaan tamarta shaqada ee rogaha.

     

    Xalka:

    Marka loo eego sifooyinka heerkulka qaybaha PV, hoos u dhaca heerkulka deegaanka, ayaa kor u kacaya tamarta wax soo saarka. Waxaa lagu talinayaa in la habeeyo kala duwan oo danab xadhigga sida ku cad xogta inverter ah. Kala duwanaanshahan danabka ah, waxtarka inverter-ku wuu sarreeyaa, beddelayaashuna waxay weli sii wadi karaan heerka korontada bilawga ah marka ilaysku hooseeyo subaxda iyo fiidkii, mana keeni doonto in korantada DC ay dhaafto xadka sare ee korantada beddelka, taas oo horseedi doonta qaylo-dhaanta iyo xidhitaanka.

  • 2.Waxqabadka dahaarka ee nidaamka PV waa la dhimay, iska caabbinta dahaarka ee dhulka ayaa ka yar 2MQ, iyo fariimaha khaladka ah "Isolation error" iyo "Isolation Fault" ayaa la soo bandhigay.

    Sababta dhacdada:

    Guud ahaan qaybaha PV, sanduuqyada isgoysyada, fiilooyinka DC, rogoyaasha, fiilooyinka AC, terminalka, iyo qaybaha kale ee xariiqda ilaa dhulka gaaban ee wareegga gaaban ama waxyeellada lakabka, xirayaasha xadhigga dabacsan ee biyaha, iyo wixii la mid ah.

     

    Xalka:

    Isku xidhka shabkada, iyo inverter, hubi caabbinta dahaadhka qayb kasta oo ka mid ah fiilada dhulka, ogow dhibaatada, oo beddel fiilada u dhigma ama isku xidhaha!

     

  • 3.Excessive danab wax soo saarka ee dhinaca AC, taasoo keentay in inverter in la xiro ama derate la ilaalinta?

    Sababta dhacdada:

    Waxaa jira arrimo badan oo saameeya awoodda wax soo saarka ee dhirta korontada PV, oo ay ku jiraan caddadka shucaaca qorraxda, xagal janjeera ee moduleka unugyada qoraxda, xannibaadda boodhka iyo hadhku, iyo sifooyinka heerkulka moduleka.

    Awoodda nidaamku way yar tahay sababtoo ah qaabeynta iyo rakibidda nidaamka khaldan.

     

    Sdoorashada

    (1) Tijaabi in awoodda qayb kasta oo PV ku filan tahay ka hor inta aan la rakibin.

     

    (2) Meesha lagu rakibay ma aha mid hawo fiican leh, kulaylka rookuhuna kuma fidin wakhtiga, ama si toos ah ayey u ifaysaa iftiinka qorraxda, taas oo sababta heerkulka beddelka inuu aad u sarreeyo.

     

    (3) Hagaaji xagasha rakibaadda iyo jihaynta moduleka PV.

     

    (4) Ka hubi moduleka hadhka iyo boodhka.

     

    (5) Kahor intaadan rakibin xadhkaha badan, hubi tamarta furan ee xadhig kasta oo aan ka badnayn 5V. Haddii danabku khalad yahay, hubi fiilooyinka iyo xidhayaasha.

     

    (6) Marka la rakibayo, waxaa lagu geli karaa kooxo. Markaad gasho koox kasta, qor awooda koox kasta, farqiga u dhexeeya awooda xadhiguna waa inaanu ka badnayn 2%.

     

    (7) Inverter-ku waxa uu leeyahay laba fursadood oo MPPT ah, si kasta oo ay tahay awoodda wax gelinta ayaa ah 50% oo keliya wadarta guud ee awoodda. Mabda 'ahaan, dariiq kasta waa in la nashqadeeyaa oo lagu rakibaa awood siman, haddii kaliya lagu xiro hal waddo terminal MPPT, awoodda wax soo saarka ayaa la dhimi doonaa kala badh.

     

    (8) Xidhiidhka fiilada oo aad u liidata, fiilada aad ayuu u dheer yahay, dhexroorka siligga ayaa aad u dhuuban, waxaa jira luminta korantada, oo ugu dambeyntii sababa khasaare koronto.

     

    (9) Ogow in danabku uu ku dhex jiro xadka korantada ka dib marka qaybaha si isdaba joog ah loogu xiro, iyo waxtarka nidaamka waa la dhimi doonaa haddii korontadu aad u hooseyso.

     

    (10) Awoodda koronto-ku-xidhka AC-da ee warshadda korantada PV aad ayay u yar tahay si ay u buuxiso shuruudaha wax-soo-saarka beddelka.